Title of article :
Characterization of the first true coaxial 18-fold segmented -type prototype HPGe detector for the gerda project
Author/Authors :
Abt، نويسنده , , I. and Caldwell، نويسنده , , A. and Gutknecht، نويسنده , , D. and Krِninger، نويسنده , , K. and Lampert، نويسنده , , M. and Liu، نويسنده , , X. and Majorovits، نويسنده , , B. and Quirion، نويسنده , , D. and Stelzer، نويسنده , , F. and Wendling، نويسنده , , P.، نويسنده ,
Pages :
11
From page :
574
To page :
584
Abstract :
The first true coaxial 18-fold segmented n -type HPGe prototype detector produced by Canberra-France for the GERDA neutrinoless double beta-decay project was tested both at Canberra-France and at the Max-Planck-Institut für Physik in Munich. The main characteristics of the detector are given and measurements concerning detector properties are described. A novel method to establish contacts between the crystal and a Kapton cable is presented.
Keywords :
Germanium detectors , Double beta decay , segmentation
Journal title :
Astroparticle Physics