Author/Authors :
Barnyakov، نويسنده , , A.Yu. and Barnyakov، نويسنده , , M.Yu. and Bobrovnikov، نويسنده , , V.S. and Buzykaev، نويسنده , , A.R. and Tsigankov، نويسنده , , D.A. and Kononov، نويسنده , , S.A. and Kravchenko، نويسنده , , E.A. and Onuchin، نويسنده , , A.P.، نويسنده ,
Abstract :
The development of photomultiplier tubes with microchannel plates (MCP PMT) in Novosibirsk began 10 years ago. MCP PMTs are compact photodetectors with a record time resolution which can work in a strong magnetic field. The system of aerogel Cherenkov counters ASHIPH based on these PMTs (80 PMTs, 500 liters of aerogel) has been working in the KEDR detector since 2003. The main parameters of these PMTs are listed. It is shown that the photocathode life time cannot be expressed correctly in the units of the collected anode charge. The recent optimization of the MCP PMT design is described.
Keywords :
Photocathode life time , MCP PMT , Aging effect , Cherenkov counters