Author/Authors :
Kotikalapudi، Rosaiah نويسنده Department of Animal Biotechnology, Sandor Life Sciences Pvt. Ltd., Hyderabad, India , , Patel، Rajesh K. نويسنده Department of Animal Biotechnology, Sandor Animal Biogenics Pvt. Ltd., Hyderabad, India ,
Abstract :
Blood collection in heparin tubes for cytogenetic, and ethylenediaminetetraacetic acid
(EDTA) tubes for molecular genetics applications respectively, are routine practices everywhere.
If blood samples are required for cytogenetics as well as DNA work, two samples
from each animal are usually collected, which leads to wastage of time and money. The
present study tried to explore the possibilities of collecting a single blood sample in a
heparinised tube for use in both applications. Two blood samples were collected from the
same animals; one in a heparin tube and the other in an EDTA tube. DNA was extracted
and stored at the same temperature and for the same durations. Comparative studies
revealed that the DNA samples extracted from blood using these two different coagulants
give more or less the same quality of results especially for polymerase chain reaction
(PCR) based applications in cattle. The purpose of the present study was to establish the
possibility of using heparin blood for chromosomal studies as well as for molecular biology.
Such a practice will obviously save time and money in collecting samples in duplicate.