Title of article :
A new fast two-stage GL charge division method for a very long MSGC for large-area radiation imaging
Author/Authors :
Siritiprussamee، نويسنده , , P. and Fujita، نويسنده , , K. and Takahashi، نويسنده , , H. and Niko، نويسنده , , H. and Nishi، نويسنده , , K. and Toyokawa، نويسنده , , H. and Furusaka، نويسنده , , M. and Ino، نويسنده , , T. and Kishimoto، نويسنده , , S. and Shimizu، نويسنده , , H.M. and Kanazawa، نويسنده , , M.، نويسنده ,
Pages :
4
From page :
1119
To page :
1122
Abstract :
We present a novel readout method; a fast two-stage Global Local (GL) charge division method. The new readout method is to utilize two coincident signals to localize position. It can greatly improve a spatial resolution when applies to a high signal-to-noise ratio (SNR) detector. We have implemented the new readout method in very long microstrip gas counters (MSGCs). Prototype detectors, which have 640.8 mm of an active length, have been designed, fabricated and evaluated. The principle of the new readout method was confirmed. The spatial resolution was 1.15 mm with good uniformity and good linearity.
Keywords :
Readout method , Two-stage GL charge division method , MSGC , Position sensitive detector , Gas detector
Journal title :
Astroparticle Physics
Record number :
2030563
Link To Document :
بازگشت