Title of article :
On the importance of measuring all three components of the remanent field in radiation-induced demagnetization experiments
Author/Authors :
Maréchal، نويسنده , , X.-M. and Bizen، نويسنده , , Paul T. and Asano، نويسنده , , Y. and Kitamura، نويسنده , , H.، نويسنده ,
Pages :
3
From page :
1594
To page :
1596
Abstract :
In the following we present a new analysis of the data obtained after an irradiation of magnets with a 2 GeV electron beam under various conditions (with or without a target placed in front of the magnets). This analysis, based on the measured magnetic field, indicates the importance of a precise determination of the three components of the magnetization for a better understanding of the demagnetization process.
Keywords :
Magnetic field , Demagnetization , NdFeB magnet , Undulator , electron beam , Neutron , Irradiation
Journal title :
Astroparticle Physics
Record number :
2030679
Link To Document :
بازگشت