Author/Authors :
Aharrouche، نويسنده , , M. and Colas، نويسنده , , J. and Di Ciaccio، نويسنده , , L. and El Kacimi، نويسنده , , M. and Gaumer، نويسنده , , O. and Gouanère، نويسنده , , M. and Goujdami، نويسنده , , D. and Lafaye، نويسنده , , R. and Laplace، نويسنده , , S. and Le Maner، نويسنده , , C. and Neukermans، نويسنده , , L. and Perrodo، نويسنده , , P. and Poggioli، نويسنده , , L. and Prieur، نويسنده , , D. and Przysiezniak، نويسنده , , H. and ، نويسنده ,
Abstract :
The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 5 ‰ and typical global constant terms of 6 ‰ are measured for the barrel and endcap modules.
Keywords :
Particle detectors , Energy resolution and uniformity , High Energy Physics , Calorimeters