Author/Authors :
Matsumura، نويسنده , , Paul T. and Asano، نويسنده , , Y. and Chiba، نويسنده , , Melissa R. and Hashimoto، نويسنده , , T. and Miura، نويسنده , , A. and Shimizu، نويسنده , , H. and Tajima، نويسنده , , Y. and Yoshida، نويسنده , , H.Y.، نويسنده ,
Abstract :
A sharp gas-bremsstrahlung beam with an energy up to 8 GeV is available at insertion device (ID) beamlines at SPring-8. As a practical use of the beam, a test experiment for a 3 × 3 PWO calorimeter has been performed at an ID beamline, BL11XU, to measure the position of the incident gas-bremsstrahlung beam impinging on the calorimeter. The obtained position resolution is ( ( 2.76 ± 0.02 ) / E ) 2 + ( 0.30 ± 0.04 ) 2 mm , E in GeV, at the center of the calorimeter, which is consistent with the result previously obtained with a low-energy electron beam. Despite limited beam-energy information, the pencil-like photon beam generated on ID beamlines works well for a measurement of the position resolution of electromagnetic calorimeters.
Keywords :
Lead tungstate , SPring-8 , Photon beam , Calorimeter