Title of article :
Performances of 4H-SiC Schottky diodes as neutron detectors
Author/Authors :
Lo Giudice، نويسنده , , Alessandro and Fasolo، نويسنده , , Floriana and Durisi، نويسنده , , Elisabetta and Manfredotti، نويسنده , , Claudio and Vittone، نويسنده , , Ettore and Fizzotti، نويسنده , , Franco and Zanini، نويسنده , , Alba and Rosi، نويسنده , , Giancarlo، نويسنده ,
Pages :
4
From page :
177
To page :
180
Abstract :
Large area 4H-SiC Schottky diodes equipped with a 6LiF converter were tested as neutron detectors in the epithermal column realized for Boron Neutron Capture Therapy (BNCT) applications at the fast reactor TAPIRO (ENEA Casaccia Roma). The neutron spectra were assessed using the Monte Carlo code MCNP-4C. The performances of SiC detectors were evaluated with neutron fluences in the range of 109–1013 cm−2 which is typical for BNCT. Spectra of alpha and tritium particles generated by 6Li(n,α)3H reaction were collected at various neutron fluences and spectra obtained by interposing polyethylene moderators of different thickness. Only weak damaging effects primarily due to the alpha particles were observed; at neutron fluence of 1013 cm−2 the count rate decreased by <0.3%. The experimental results were compared with the theoretical ones calculated using MCNP-4C and SRIM codes.
Keywords :
boron neutron capture therapy , Epitaxial silicon carbide , Neutron beam monitoring , MCNP , radiation detector , neutron detection
Journal title :
Astroparticle Physics
Record number :
2031337
Link To Document :