Title of article :
Reasons why Plutonium 242 is the best fission chamber deposit to monitor the fast component of a high neutron flux
Author/Authors :
Filliatre، نويسنده , , P. and Oriol، نويسنده , , L. and Jammes، نويسنده , , C. and Vermeeren، نويسنده , , L.، نويسنده ,
Pages :
9
From page :
510
To page :
518
Abstract :
The FNDS project aims at developing fission chambers to measure on-line the fast component of a high neutron flux ( ∼ 10 14 n cm - 2 s - 1 or more) with a significant thermal component. We identify with simulations the deposits of fission chambers that are best suited to this goal. We address the question of the evolution of the deposit by radiative capture and decay. A deposit of 242Pu appears as the best choice, with a high initial sensitivity to fast neutrons only slowly degrading under irradiation. The effect of unavoidable impurities was assessed: small concentrations of 241Pu and 239Pu can be tolerated.
Keywords :
Fission chambers , Fast neutron flux , SIMULATION
Journal title :
Astroparticle Physics
Record number :
2032505
Link To Document :
بازگشت