Ueshima، نويسنده , , K. and Abe، نويسنده , , K. and Iida، نويسنده , , T. and Ikeda، نويسنده , , M. and Kobayashi، نويسنده , , K. and Koshio، نويسنده , , Y. and Minamino، نويسنده , , A. and Miura، نويسنده , , M. and Moriyama، نويسنده , , S. and Nakahata، نويسنده , , M. and Nakajima، نويسنده , , Y. and Ogawa، نويسنده , , H. and Sekiya، نويسنده , , H. and Shiozawa، نويسنده , , M. and Suzuki، نويسنده , , Y. and Takeda، نويسنده , , A. and Takeuchi، نويسنده ,
Abstract :
The intensity of scintillation light emission from liquid xenon at room temperature was measured. The scintillation light yield at 1 ∘ C was measured to be 0.64 ± 0.02 (stat.) ± 0.06 (sys.) of that at - 100 ∘ C . Using the reported light yield at - 100 ∘ C (46 photons/keV), the measured light yield at 1 ∘ C corresponds to 29 photons/keV. This result shows that liquid xenon scintillator provides high light yield even at room temperature.