• Title of article

    Transparency of 0.2% GdCl3 doped water in a stainless steel test environment

  • Author/Authors

    Coleman، نويسنده , , W. and Bernstein، نويسنده , , A. and Dazeley، نويسنده , , S. and Svoboda، نويسنده , , R.، نويسنده ,

  • Pages
    7
  • From page
    339
  • To page
    345
  • Abstract
    The possibility of neutron and neutrino detection using water Cherenkov detectors doped with gadolinium holds the promise of constructing very large high-efficiency detectors with wide-ranging application in basic science and national security. This study addresses a major concern regarding the feasibility of such detectors: the transparency of the doped water to the ultraviolet Cherenkov light. We report on experiments conducted using a 19-m water transparency measuring instrument and associated material test tank. Sensitive measurements of the transparency of water doped with 0.2% GdCl3 at 337, 400 and 420 nm were made using this instrument. These measurements indicate that the use of GdCl3 in stainless steel constructed water Cherenkov detectors is problematic.
  • Keywords
    Neutrino , DSNB , transparency , Gadolinium , Water Cherenkov detectors , Neutron
  • Journal title
    Astroparticle Physics
  • Record number

    2032818