Title of article :
Polymeric micro-channel-based functionalisation system for micro-cantilevers
Author/Authors :
Nordstrِm، نويسنده , , Maria Ll. Calleja، نويسنده , , Montserrat and Boisen، نويسنده , , Anja، نويسنده ,
Pages :
6
From page :
281
To page :
286
Abstract :
A micro-channel system intended for functionalising micro-cantilevers used for biochemical detection has been designed, realised and characterised. The chip is fabricated in the resist SU-8, which is a photosensitive polymer offering a fast, cost-efficient and easy processing. Cantilevers present a new platform for biochemical detection with a high sensitivity. This micro-channel system is used for treating such a cantilever array with probe molecules prior to detection and it can also be used as the analysis set-up. The design of the micro-channel system provides a simple way of coating separate sections of a cantilever array with different probe molecules. The use of this channel system eliminates the time-consuming step of addressing each cantilever individually to obtain an array functionalised with different probe molecules. Using this micro-channel system in combination with a cantilever array establishes a method of detecting multiple target molecules simultaneously. Fluorescence experiments have been performed to show the working principle of the micro-channel system in combination with a cantilever array.
Keywords :
fluorescence , Biochemical detection , Micro-channels , Biosensors
Journal title :
Astroparticle Physics
Record number :
2051817
Link To Document :
بازگشت