Title of article :
Simultaneous determination of film permeability to H2O2 and substrate surface area coverage of overoxidized polypyrrole
Author/Authors :
Reyes De Corcuera، نويسنده , , J.I and Cavalieri، نويسنده , , R.P and Powers، نويسنده , , J.R، نويسنده ,
Issue Information :
دوماهنامه با شماره پیاپی سال 2004
Pages :
9
From page :
71
To page :
79
Abstract :
A method to simultaneously determine film permeability and surface area coverage of electrochemically generated and overoxidized polypyrrole (PPY) films on platinum is presented. The method, similar to the Koutecky–Levich approach, is based on the rotatin
Keywords :
Enzyme biosensor , Overoxidized polypyrrole , Permeability , rotating disk electrode , Surface area
Journal title :
Synthetic Metals
Serial Year :
2004
Journal title :
Synthetic Metals
Record number :
2080101
Link To Document :
بازگشت