Title of article :
A real time detection of the ovarian tumor associated antigen 1 (OVTA 1) in human serum by quartz crystal microbalance immobilized with anti-OVTA 1 polyclonal chicken IgY antibodies
Author/Authors :
Sadhasivam، نويسنده , , S. and Chen، نويسنده , , Jung-Chih and Savitha، نويسنده , , S. and Lin، نويسنده , , Feng-Huei and Yang، نويسنده , , Yi-Yuan and Lee، نويسنده , , Chi-Hsin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
6
From page :
2073
To page :
2078
Abstract :
In this study, we developed a sensitive quartz crystal microbalance (QCM) sensor which employs the anti-ovarian tumor associated antigen 1 (OVTA 1) IgY polyclonal chicken antibodies on the crystal surface for the detection of OVTA 1 in human serum. The anti-OVTA 1 IgY antibodies were anchored on the thiol-activated sensor surface using 1-ethyl-3[3-dimethylaminopropyl] carbodiimide hydrochloride/N-hydroxysuccinimide (EDC–NHS) coupling. The responses for different concentrations of anti-OVTA 1 antibody were also studied and 40 μg/mL was favorable for homogenous antibody coverage. The QCM sensor was used to monitor both immobilization and the target binding affinity. The anti-OVTA 1 antibody based QCM has allowed the competent detection of OVTA 1 in a high linear range of 0.5–10 μg/mL. The total time needed to complete the detection was as short as 5–6 h. The regeneration studies demonstrated that the proposed sensor was reusable up to 9 cycles with a slight loss in binding affinity. The detection of OVTA 1 in human serum allows a potential exploitation of the anti-OVTA 1 polyclonal antibody based QCM immunoassay for the screening of OVTA 1 antigen.
Keywords :
Ovarian cancer , Human serum , QCM , Immunosensors , OVTA 1 antigen , Polyclonal chicken IgY antibodies
Journal title :
Materials Science and Engineering C
Serial Year :
2012
Journal title :
Materials Science and Engineering C
Record number :
2102198
Link To Document :
بازگشت