Title of article :
Elasticity assessment of electrospun nanofibrous vascular grafts: A comparison with femoral ovine arteries
Author/Authors :
Suarez Bagnasco، نويسنده , , D. and Montini Ballarin، نويسنده , , F. and Cymberknop، نويسنده , , L.J. and Balay، نويسنده , , G. and Negreira، نويسنده , , Gregg C. and Abraham، نويسنده , , G.A. and Armentano، نويسنده , , R.L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
9
From page :
446
To page :
454
Abstract :
Development of successful small-diameter vascular grafts constitutes a real challenge to biomaterial engineering. In most cases these grafts fail in-vivo due to the presence of a mechanical mismatch between the native vessel and the vascular graft. Biomechanical characterization of real native vessels provides significant information for synthetic graft development. Electrospun nanofibrous vascular grafts emerge as a potential tailor made solution to this problem. PLLA-electrospun nanofibrous tubular structures were prepared and selected as model bioresorbable grafts. An experimental setup, using gold standard and high resolution ultrasound techniques, was adapted to characterize in vitro the poly(l-lactic acid) (PLLA) electrospun structures. The grafts were subjected to near physiologic pulsated pressure conditions, following the pressure–diameter loop approach and the criteria stated in the international standard for cardiovascular implants-tubular vascular prostheses. Additionally, ovine femoral arteries were subjected to a similar evaluation. Measurements of pressure and diameter variations allowed the estimation of dynamical compliance (%C, 10− 2 mm Hg) and the pressure–strain elastic modulus (EPε, 106 dyn cm− 2) of the abovementioned vessels (grafts and arteries). Nanofibrous PLLA showed a decrease in %C (1.38 ± 0.21, 0.93 ± 0.13 and 0.76 ± 0.15) concomitant to an increase in EPε (10.57 ± 0.97, 14.31 ± 1.47 and 17.63 ± 2.61) corresponding to pressure ranges of 50 to 90 mm Hg, 80 to 120 mm Hg and 100 to 150 mm Hg, respectively. Furthermore, femoral arteries exhibited a decrease in %C (8.52 ± 1.15 and 0.79 ± 0.20) and an increase in EPε (1.66 ± 0.30 and 15.76 ± 4.78) corresponding to pressure ranges of 50–90 mm Hg (elastin zone) and 100–130 mm Hg (collagen zone). Arterial mechanics framework, extensively applied in our previous works, was successfully used to characterize PLLA vascular grafts in vitro, although its application can be directly extended to in vivo experiences, in conscious and chronically instrumented animals. The specific design and construction of the electrospun nanofibrous PLLA vascular grafts assessed in this work, showed similar mechanical properties as the ones observed in femoral arteries, at the collagen pressure range.
Keywords :
mechanical properties , PLLA , electrospinning , Vascular grafts , Pressure–diameter loop
Journal title :
Materials Science and Engineering C
Serial Year :
2014
Journal title :
Materials Science and Engineering C
Record number :
2105265
Link To Document :
بازگشت