Title of article :
Effects of amphiphilic chitosan-g-poly(ε-caprolactone) polymer additives on paclitaxel release from drug eluting implants
Author/Authors :
Shi، نويسنده , , Weibin and Gu، نويسنده , , Chunhua and Jiang، نويسنده , , Han and Zhang، نويسنده , , Mengru and Lang، نويسنده , , Meidong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
8
From page :
502
To page :
509
Abstract :
Bioresorbable polymer stents have been proposed as promising medical implants to avoid long-term safety concerns and other potential issues caused by traditional materials. As an important member, poly(ε-caprolactone) (PCL) was used as the implant matrix with different drug loadings. To better regulate drug release rate, the hydrophilicity of PCL was adjusted by addition of amphiphilic graft copolymers, chitosan-g-poly(ε-caprolactone) (CP). The in vitro release results indicated that the improvement of bulk hydrophilicity could accelerate drug release better than that of surface coating. The optimum additive amount was 25% with CP9. Further study showed that the effect of aspirin molecules displayed no obvious difference to that of CP macromolecules on drug release rate. Moreover, these release profiles were fitted with mathematical models. The similarities were evaluated with similarity factors. Scanning electron microscopy (SEM) images displayed surface/cross-section morphologies of pure PCL and modified implants before and after release.
Keywords :
Paclitaxel , Graft copolymer , Drug release , Poly(?-caprolactone)
Journal title :
Materials Science and Engineering C
Serial Year :
2014
Journal title :
Materials Science and Engineering C
Record number :
2105277
Link To Document :
بازگشت