Title of article :
A simple method to recover Norovirus from fresh produce with large sample size by using histo-blood group antigen-conjugated to magnetic beads in a recirculating affinity magnetic separation system (RCAMS)
Author/Authors :
Tian، نويسنده , , Peng and Yang، نويسنده , , David and Mandrell، نويسنده , , Robert، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
5
From page :
223
To page :
227
Abstract :
Human norovirus (NoV) outbreaks are major food safety concerns. The virus has to be concentrated from food samples in order to be detected. PEG precipitation is the most common method to recover the virus. Recently, histo-blood group antigens (HBGA) have been recognized as receptors for human NoV, and have been utilized as an alternative method to concentrate human NoV for samples up to 40 mL in volume. However, to wash off the virus from contaminated fresh food samples, at least 250 mL of wash volume is required. Recirculating affinity magnetic separation system (RCAMS) has been tried by others to concentrate human NoV from large-volume samples and failed to yield consistent results with the standard procedure of 30 min of recirculation at the default flow rate. Our work here demonstrates that proper recirculation time and flow rate are key factors for success in using the RCAMS. The bead recovery rate was increased from 28% to 47%, 67% and 90% when recirculation times were extended from 30 min to 60 min, 120 min and 180 min, respectively. The kinetics study suggests that at least 120 min recirculation is required to obtain a good recovery of NoV. In addition, different binding and elution conditions were compared for releasing NoV from inoculated lettuce. Phosphate-buffered saline (PBS) and water results in similar efficacy for virus release, but the released virus does not bind to RCAMS effectively unless pH was adjusted to acidic. Either citrate-buffered saline (CBS) wash, or water wash followed by CBS adjustment, resulted in an enhanced recovery of virus. We also demonstrated that the standard curve generated from viral RNA extracted from serially-diluted virus samples is more accurate for quantitative analysis than standard curves generated from serially-diluted plasmid DNA or transcribed-RNA templates, both of which tend to overestimate the concentration power. The efficacy of recovery of NoV from produce using RCAMS was directly compared with that of the PEG method in NoV inoculated lettuce. 40, 4, 0.4, and 0.04 RTU can be detected by both methods. At 0.004 RTU, NoV was detectable in all three samples concentrated by the RCAMS method, while none could be detected by the PEG precipitation method. RCAMS is a simple and rapid method that is more sensitive than conventional methods for recovery of NoV from food samples with a large sample size. In addition, the RTU value detected through RCAMS-processed samples is more biologically relevant.
Keywords :
Norovirus , Virus concentration , Histo-blood group antigen , PEG precipitation method , Recirculating affinity magnetic separation system , binding kinetics
Journal title :
International Journal of Food Microbiology
Serial Year :
2011
Journal title :
International Journal of Food Microbiology
Record number :
2116800
Link To Document :
بازگشت