Title of article :
Influence of chromium interlayer on the adhesion of porcelain to machined titanium as determined by the strain energy release rate
Author/Authors :
Basem Elsaka، نويسنده , , Shaymaa E. and Hamouda، نويسنده , , Ibrahim M. and Elewady، نويسنده , , Yehia A. and Abouelatta، نويسنده , , Ossama B. and Swain، نويسنده , , Michael V.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
Objectives
tudy evaluated the effect of a chromium interlayer deposited by electroplating on the adhesion between titanium and porcelain by means of strain energy release rate (G-value (J/m2) or interfacial toughness).
s
y rectangular specimens of commercially pure titanium (CP Ti) plates grade II (8 mm × 30 mm × 1.5 mm) were prepared. The specimens were divided into seven groups according to the electroplating treatment; Gr 1 (control without electroplating, n = 10); Gr 2 (5% (w/v) chromium nitrate solution for 30 min, n = 10); Gr 3 (5% (w/v) chromium nitrate solution for 60 min, n = 10); Gr 4 (5% (w/v) chromium nitrate solution for 120 min, n = 10); Gr 5 (10% (w/v) chromium nitrate solution for 30 min, n = 10); and Gr 6 (10% (w/v) chromium nitrate solution for 60 min, n = 10) and Gr 7 (10% (w/v) chromium nitrate solution for 120 min, n = 10). Each group was further equally divided into two subgroups according to the type of porcelain used. Two titanium–porcelains (Vita Titankeramik and Triceram) were applied to each subgroup (n = 5). The G-value was measured with a four-point bending configuration. Following fracture testing, specimens were examined with a scanning electron microscope (SEM). Data were analysed using ANOVA and Tukeyʹs test.
s
on values were significantly affected by the type of electroplating treatment (P < 0.05) and by the type of porcelain (P < 0.05). The CP Ti/Vita Titankeramik (0.5 h 5% (w/v), 1 h 5% (w/v) and 0.5 h 10% (w/v)) groups showed the highest G-value (36.94 ± 3.25, 38.87 ± 7.91 and 37.22 ± 5.76 J/m2) amongst their groups. The CP Ti/Triceram (0.5 h 5% (w/v) and 0.5 h 10% (w/v)) groups (26.72 ± 4.36 and 26.94 ± 3.52 J/m2) were statistically significantly different from the control group (14.99 ± 1.50 J/m2) (P < 0.05). A definitive relationship was found between Cr film thickness and G-value for both porcelain materials.
sion
on between porcelain and CP Ti can be improved by the use of chromium interlayer prior to porcelain firing.
Keywords :
Adhesion , Interfacial bond energy , Strain energy release rate , Chromium , Porcelain , Titanium , Metal–ceramic , Electroplating
Journal title :
Journal of Dentistry
Journal title :