Title of article :
Degree of conversion and microhardness of TPO-containing resin-based composites cured by polywave and monowave LED units
Author/Authors :
Santini، نويسنده , , Ario and Miletic، نويسنده , , Vesna and Swift، نويسنده , , Michael D. and Bradley، نويسنده , , Mark، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
8
From page :
577
To page :
584
Abstract :
Objectives ermine the degree of conversion (DC) and Knoop microhardness (KHN) of resin-based composites (RBCs) containing trimethylbenzoyl-diphenylphosphine oxide (TPO) cured by polywave or monowave LED light-curing units (LCUs). s groups (each n = 5) of Tetric EvoCeram (Ivoclar Vivadent), Vit-l-escence (Ultradent) and Herculite XRV Ultra (Kerr) were prepared in Teflon moulds (5 mm in diameter and 2 mm thick) and cured with polywave Bluephase® G2 (Ivoclar Vivadent), polywave Valo (Ultradent) or monowave Bluephase® (Ivoclar Vivadent; control) resulting in 9 groups. DC and KHN were determined using micro-Raman spectroscopy and Knoop microhardness, respectively. High-performance liquid chromatography and nuclear magnetic resonance spectroscopy were used to confirm the presence or absence of TPO in the three uncured materials. Data were statistically analysed using two-way and one-way ANOVA and DC and KHN were correlated using Pearsonʹs correlation (α = 0.05). s s confirmed in Tetric EvoCeram and Vit-l-escence but not in Herculite XRV Ultra. All three LCUs produced comparable KHN for Tetric EvoCeram and Herculite XRV Ultra (p > 0.05). Both polywave LCUs resulted in significantly higher KHN for Vit-l-escence and higher DC in Tetric EvoCeram and Vit-l-escence than the monowave Bluephase® (p < 0.05). Conversely, Bluephase® showed higher DC than the two polywave LCUs in Herculite XRV Ultra (p < 0.05). Pearsonʹs correlation coefficient was r = 0.818. sions ve LED LCUs improved monomer to polymer conversion and KHN in the two TPO-containing RBCs, but not in Herculite XRV Ultra. DC and KHN were linearly correlated in all three RBCs. Vit-l-escence showed the highest DC and KHN of the three materials tested. al significance e of polywave LEDs significantly improves both the DC and KHN of materials which contain TPO. This should be taken into account when curing bleached shades of RBCs even if the manufacturers do not indicate the presence of TPO in their materials.
Keywords :
Conversion , Hardness , Raman , Spectroscopy , TPO , Polywave LED , Camphorquinone , Resin-based composites , Initiators
Journal title :
Journal of Dentistry
Serial Year :
2012
Journal title :
Journal of Dentistry
Record number :
2129747
Link To Document :
بازگشت