Title of article :
Interaction of LED light with coinitiator-containing composite resins: Effect of dual peaks
Author/Authors :
Sim، نويسنده , , Jae-Seong and Seol، نويسنده , , Hyo-Joung and Park، نويسنده , , Jeong-Kil and Garcia-Godoy، نويسنده , , Franklin and Kim، نويسنده , , Hyung-Il and Kwon، نويسنده , , Yong Hoon، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
Objectives
ly the colour stability of composite resins has been an issue due to the emphasis on the aesthetics of restored teeth. The purpose of the present study was to investigate how dual-peak LED units affect the polymerization of coinitiator-containing composite resins.
als and methods
omposite resins [coinitiator-containing: Aelite LS Posterior (AL), Tetric EvoCeram (TE), and Vit-l-escence (VI); only CQ-containing: Grandio (GD) and Filtek Z350 (Z3)] were light cured using four different light-curing units (LCUs). Among them, Bluephase G2 (BP) and G-light (GL) were dual-peak LED LCUs. Microhardness, polymerization shrinkage, flexural, and compressive properties were measured.
s
GL had no consistent effect on the microhardness of AL, TE, and VI on the top and bottom surfaces of resin specimens. Among the specimens, AL and VI showed the least (9.86–10.41 μm) and greatest (17.58–19.21 μm) polymerization shrinkage, respectively. However, the effect of BP and GL on the shrinkage of specimens was not consistent. Among the specimens, GD showed the greatest flexural properties [strength (FS) and modulus (FM)] and TE showed the lowest flexural and compressive properties [strength (CS) and modulus (CM)]. In same resin product, maximum FS and CS differences due to the different LCUs were 10.3–21.0% and 3.6–9.2%, respectively. Furthermore, the influences of BP and GL on FS and CS were not consistent.
sion
sted dual-peak LED LCUs had no consistent synergic effect on the polymerization of coinitiator-containing composite resins as compared with QTH and single-peak LED LCUs.
al significance
al-peak LED LCUs achieve a similar degree of polymerization in coinitiator-composite resins as QTH and single-peak LED LCUs did. Choice of LCU does not appear to be a determinant of the light curing of coinitiator-composite resins.
Keywords :
Coinitiator , Polymerization , Dual-peak LED
Journal title :
Journal of Dentistry
Journal title :
Journal of Dentistry