• Title of article

    Simultaneous Spectrophotometric Determination of Heavy Metal Ions Using Several Chemometrics Methods: Effect of Different Parameters of Savitzky-Golay and Direct Orthogonal Signal Correction Filters

  • Author/Authors

    -، - نويسنده Department of Chemistry, Faculty of Sciences, K. N. Toosi University of Technology, Tehran, I. R. IRAN Rouhollahi, Ahmad , -، - نويسنده Department of Chemistry, Faculty of Sciences, K. N. Toosi University of Technology, Tehran, I. R. IRAN Tavakoli, Hossein , -، - نويسنده Department of Chemistry, Faculty of Sciences, Razi University, Kermanshah, I. R. IRAN Nayebi, Shahzad , -، - نويسنده Department of Chemistry, Faculty of Sciences, Razi University, Kermanshah, I. R. IRAN Ghasemi, Jahanbakhsh , -، - نويسنده Researches and Petroleum Engineering Center of Kermanshah, Kermanshah, I. R. IRAN Noroozi, Mohammad , -، - نويسنده Researches and Petroleum Engineering Center of Kermanshah, Kermanshah, I. R. IRAN Hashemi, Majid

  • Issue Information
    فصلنامه با شماره پیاپی 42 سال 2007
  • Pages
    11
  • From page
    41
  • To page
    51
  • Abstract
    -
  • Abstract
    Direct orthogonal signal correction(DOSC) and Savitzky-Golay filters (SGF) were applied as preprocessing methods on the original and first derivative absorbance data. Principle component regression (PCR), partial least squares (PLS) and iterative target transformation factor analysis (ITTFA), were used in spectrophotometric simultaneous determination of heavy divalent metal ions, lead, zinc,mercury and cadmium,using 4-(2-pyridylazo) resorcinol (PAR) as metallochromic indicator. The optimum values of the parameters for DOSC and SGF were obtained according to REP, R2 and RMSEP functions for calibration and prediction sets. The concentration for Hg2+, Pb2+, Zn2+ and Cd2+ ions in calibration set were varied between 0 - 12.24, 0 - 9.81, 0 - 0.87 and 0 - 3.96 ppm, respectively. The experimental calibration set was composed of 35 sample solutions and the 7 solutions as prediction set using a simple lattice (4,4) mixture design. The absorption spectra were recorded from 450 to 600 nm and absorbance data were autoscaled. The effect of pH on the sensitivity and selectivity was studied in the range of 1.00 - 11.00 and pH=7.50 was chosen according to net analyte signal (NAS) as a function of pH.
  • Journal title
    Iranian Journal of Chemistry and Chemical Engineering (IJCCE)
  • Serial Year
    2007
  • Journal title
    Iranian Journal of Chemistry and Chemical Engineering (IJCCE)
  • Record number

    2151844