• Title of article

    A new tip area function for instrumented nanoindentation at extremely small contact depths

  • Author/Authors

    Liu، نويسنده , , Sheng-hong Gu، نويسنده , , Yuantong and Huang، نويسنده , , Han، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    4
  • From page
    7948
  • To page
    7951
  • Abstract
    The accuracy of measurement of mechanical properties of a material using instrumented nanoindentation at extremely small penetration depths heavily relies on the determination of the contact area of the indenter. Our experiments have demonstrated that the conventional area function could lead to a significant error when the contact depth was below 40 nm, due to the singularity in the first derivation of the function in this region and thus, the resultant unreasonable sharp peak on the function curve. In this paper, we proposed a new area function that was used to calculate the contact area for the indentations where the contact depths varied from 10 to 40 nm. The experimental results have shown that the new area function has produced better results than the conventional function.
  • Keywords
    Nanoindentation , Area function , MODULUS , Hardness
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: A
  • Serial Year
    2011
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: A
  • Record number