Abstract
The abrupt steep jump of electron cyclotron emission (ECE) signals during current ramp-down has been observed and explained by an anomalous Doppler resonance effect (ADR). The identifying process of ADR was presented based on the fast Fourier transform (FFT) technique. The threshold value for triggering a steep jump on ECE signals has been identified under different discharge conditions.
Keywords
Electron cyclotron emission , Anomalous Doppler resonance