• Title of article

    The use of a gas-filled-magnet in experiments with radioactive ion beams

  • Author/Authors

    Rehm، نويسنده , , K.E and Jiang، نويسنده , , C.L and Paul، نويسنده , , M and Blumenthal، نويسنده , , D and Gehring، نويسنده , , J and Henderson، نويسنده , , D and Nickles، نويسنده , , J and Nolen، نويسنده , , J and Pardo، نويسنده , , R.C and Roberts، نويسنده , , A.D and Schiffer، نويسنده , , J.P and Segel، نويسنده , , R.E، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    7
  • From page
    438
  • To page
    444
  • Abstract
    A detection system has been developed for experiments with radioactive beams which have considerable contamination from a stable isobar. The system uses the gas-filled magnet technique and identifies reaction products according to nuclear charge and mass with good resolution even at energies below 1 MeV/u. In a first experiment the device has been used to measure cross sections for the 18F(p, α)15O reaction in the energy range between 650 and 840 keV/u.
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1996
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2171903