Author/Authors :
Balata، نويسنده , , M. and Cadonati، نويسنده , , L. and Laubenstein، نويسنده , , M. and Heusser، نويسنده , , G. and Giammarchi، نويسنده , , M.G. and Scardaoni، نويسنده , , R. and Torri، نويسنده , , V. and Cecchet، نويسنده , , G. and de Bari، نويسنده , , A. and Perotti، نويسنده , , A.، نويسنده ,
Abstract :
The Borexino experiment, for the study of solar neutrino physics, requires radiopurity at the level of 5 × 10−16 g/g 238U equivalent (or 6 × 10−9 Bq/kg) on a detector mass of many tons of scintillator. Feasibility studies are performed in a counting test facility now operating at LNGS, which consists of 4 t of liquid scintillator viewed by 100 photomultipliers and shielded by 100 t of water. The accomplishment of this goal requires the shielding liquid, water, to be at the 10−13 g/g contamination level (1.2 × 10−6 Bq/kg) or better. This paper describes the water purification system; it consists of a combination of several purification processes to remove particulate, radioactive ions, dissolved gases and other impurities. Residual contaminations are measured by analytical or direct-counting techniques. For radon measurement, particularly challenging at this low activity levels, a low background counting method has been developed.