Title of article
Application of neutron radiography to a diagnosis of refrigerator
Author/Authors
Asano، نويسنده , , H. and Takenaka، نويسنده , , N. and Fujii، نويسنده , , T. and Murata، نويسنده , , Y. and Mochiki، نويسنده , , K. and Taguchi، نويسنده , , A. and Matsubayashi، نويسنده , , M. and Tsuruno، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
4
From page
170
To page
173
Abstract
A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized.
Keywords
Refrigerator , two-phase flows , Real-time , Diagnosis of practical machine , Cooled CCD camera
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
1996
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2173158