Title of article
Evaluation of silicon micro strip detectors with large read-out pitch
Author/Authors
Senyo، نويسنده , , K. and Hazumi، نويسنده , , M. and Kawasaki، نويسنده , , T. and Nagashima، نويسنده , , Y. and Yamamoto، نويسنده , , K. and Yamamura، نويسنده , , K. and Tsuboyama، نويسنده , , T. Cisse Haba، نويسنده , , J. and Ikeda، نويسنده , , H. and Iwasaki، نويسنده , , H. and Matsuda، نويسنده , , T. and Ozaki، نويسنده , , H. and Tanaka، نويسنده , , M. and Yamada، نويسنده , , Y. and Okuno، نويسنده , , S. and Avrillon، نويسنده , , S. and Asano، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
5
From page
123
To page
127
Abstract
For the development of the silicon micro strip detector with the pitch of the readout strips as large as 250 μm on the ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips.