Title of article :
Hard X-ray detection model for microchannel plate detectors
Author/Authors :
Victor V. and Shikhaliev، نويسنده , , P.M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
9
From page :
229
To page :
237
Abstract :
A generalized hard X-ray detection model for microchannel plate detectors has been developed. This model includes all geometrical and compositional parameters of an MCP and the energy of a detected X-ray. An analytical investigation and numerical calculation of the detection efficiency was carried out; obtained data were compared with experimental results. A square and hexagonal channel MCP were considered in addition to a traditional circular channel MCP. Moreover, it is shown that the first ones have advantages as X-ray detectors.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1997
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2176625
Link To Document :
بازگشت