Title of article :
Response of CVD diamond detectors to alpha radiation
Author/Authors :
Souw، نويسنده , , E.-K. and Meilunas، نويسنده , , R.J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
18
From page :
69
To page :
86
Abstract :
This article describes some results from an experiment with CVD diamond films used as α particle detectors. It demonstrates that bulk polarization can be effectively stopped within a reasonable time interval. This will enable detector calibration and quantitative measurement. A possible mechanism for the observed polarization quenching is discussed. It involves two types of carrier traps and a tentative band-gap model derived from the results of photoconductive current measurements. The experiment was set up mainly to investigate α detection properties of polycrystalline diamond films grown by the technique of microwave plasma enhanced chemical vapor deposition. For comparison, two commercially purchased diamond wafers were also investigated, i.e., one grown by the DC arc jet method, and the other, a type-IIa natural diamond wafer (not preselected). The best response to α particles was obtained using diamond thin-films grown by the microwave PECVD method, followed by the type-IIa natural diamond, and finally, the CVD diamond grown by the DC arc jet technique.
Keywords :
Carrier traps , Band-gap model , Alpha radiation , detector , CVD diamond , Polarization
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1997
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2176764
Link To Document :
بازگشت