Title of article :
Performance of resistive plates counters operated with mixtures containing different freons
Author/Authors :
Arena، نويسنده , , V. and Boca، نويسنده , , G. and Bonomi، نويسنده , , G. and Gianini، نويسنده , , G. and Liguori، نويسنده , , G. and Merlo، نويسنده , , M. and Ratti، نويسنده , , S.P. and Riccardi، نويسنده , , C. and Viola، نويسنده , , L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
9
From page :
156
To page :
164
Abstract :
We present the performance of Resistive Plates Counters filled with gas mixtures containing different freons. Efficiency, single rate, cluster size were measured and compared. In particular, the charge collected by single strips has been compared to that obtained with a mixture containing R13B1 freon no longer allowed in several countries. Preliminary results show that R116 seems to be a good replacement, leading to performance similar to that obtained using R13B1 freon.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1997
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2176781
Link To Document :
بازگشت