Title of article :
A time-of-flight spectrometer with pulse-shape discrimination for the measurement of double-differential charged-particle emission cross sections
Author/Authors :
Takahashi، نويسنده , , A. and Murata، نويسنده , , I. and Kokooo and Ogino، نويسنده , , S. and Murakami، نويسنده , , Y. and Nishizawa، نويسنده , , H. and Kondo، نويسنده , , T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
11
From page :
93
To page :
103
Abstract :
Based on the two-dimensional analysis of energy and time-of-flight spectra, combined with the pulse-shape discrimination technique using a CsI(Tl) scintillation detector, a charged-particle spectrometer was developed to measure double-differential charged-particle emission cross sections with 14 MeV incident neutrons. Using this spectrometer, proton emission cross sections for Fe and α-particle emission cross sections for Be were measured to confirm the basic performance of the spectrometer. The measured data were compared with other experimental results, theoretical calculations and evaluations. Also, a model calculation based on kinematics for α-particle emission from Be was presented.
Keywords :
Charged-particle spectrometer , Double-differential cross section , Time-of-flight , CsI(Tl) scintillation detector , 14 MeV neutron , Pulse-shape discrimination