Title of article :
Aging measurement in wire chamber filled with dimethyl ether
Author/Authors :
Blinov، نويسنده , , V.E and Groshev، نويسنده , , V.R، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
3
From page :
26
To page :
28
Abstract :
Various methods for the measurement of wire chamber aging were analyzed and a more adequate procedure was proposed. The dependence of the aging rate R for DME-filled wire chamber of the materials and gain was investigated. For the drift chamber of the KEDR detector, R equals 45%/(C/cm). We conclude that, with careful choice of materials, the DME-filled drift chamber can operate without considerable aging effects.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1998
Journal title :
Nuclear Instruments and Methods in Physics Research Section A