Title of article
High-density calorimeter with scintillating fiber readout
Author/Authors
Bamberger، نويسنده , , A and Hauser، نويسنده , , M and Markun، نويسنده , , P and Wِlfle، نويسنده , , S، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
4
From page
554
To page
557
Abstract
A prototype of the electromagnetic section of a high-density calorimeter was constructed and tested with electrons up to 75 GeV. Using W (Pb) as absorber material, and a “Spaghetti”-type readout the average density was 15.2 (9.8) g/cm3. The resolution for electromagnetic showers was measured to be σ(E)/E=53%/E⊕6% for W and σ(E)/E=28%/E⊕8% for Pb.