Author/Authors :
Aulchenko، نويسنده , , V.M. and Baibusinov، نويسنده , , B.O. and Baru، نويسنده , , S.E and Kenik، نويسنده , , I.A and Myskin، نويسنده , , V.O and Savinov، نويسنده , , G.A and Shamanaeva، نويسنده , , L.I and Talyshev، نويسنده , , A.A. and Usov، نويسنده , , Yu.V، نويسنده ,
Abstract :
To accept, select and process the information of colliding beam experiments we have constructed a DAQ called “KLYUKVA”. The main principles are: distribution of 500 MHz clock frequency from one center for measurements of time intervals; disposition of all registering electronics in special crates with fast databus and triggers communications; using of fast processors with built-in algorithms as crate controllers. This DAQ with triggers can provide 250 selected and processed events per second for on-line computer with ∼15% of losses. The DAQ works now on all three INP detectors: KEDR, SND and KMD-2.