Author/Authors :
Carlén، نويسنده , , L and El Chenawi، نويسنده , , K and Enosawa، نويسنده , , K and Garpman، نويسنده , , S and Gustafsson، نويسنده , , H.-إ and Kurata، نويسنده , , M and Lِhner، نويسنده , , H and Martin، نويسنده , , M and Miake، نويسنده , , Y and Miyamoto، نويسنده , , Y and Naef، نويسنده , , H and Nilsson، نويسنده , , P and Nishimura، نويسنده , , S and Nystrand، نويسنده , , J and Oskarsson، نويسنده , , A and ضsterman، نويسنده , , L and Otterlun، نويسنده ,
Abstract :
We have developed large area multi-step avalanche chambers with electronic readout for tracking in a very high multiplicity environment in the WA98 experiment at the CERN SPS. The operational characteristics of the detection system is reported. The reconstruction efficiency of the chambers varies with the density of charged particles in the range of 91–96%. The position resolution has been found to be 0.5 and 1.7 mm in the horizontal and vertical directions, respectively.
Keywords :
MSAC , Pad readout , electronic , Tracking , Position resolution , efficiency , Multi-step avalanche chamber