Title of article
Pulse-shape discrimination techniques for correcting the effects of radiation damage in germanium coaxial detectors
Author/Authors
Ho، نويسنده , , W.C.G and Boggs، نويسنده , , S.E and Lin، نويسنده , , R.P and Slassi-Sennou، نويسنده , , S and Madden، نويسنده , , N.W. and Pehl، نويسنده , , R.H and Hull، نويسنده , , E.L، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
8
From page
507
To page
514
Abstract
Pusle-shape discrimination (PSD) techniques on current pulses from coaxial germanium detectors can significantly correct for charge losses due to hole trapping caused by radiation damage. Numerical simulations of PSD indicate that by measuring the two largest photon interaction locations and correcting the energy depositions separately, a significant recovery of the energy resolution and the Gaussian line shape of narrow lines in radiation damaged detectors can be obtained.
Keywords
Germanium , Radiation damage , Gamma-Ray , Detectors