• Title of article

    Calibration of the DELPHI HPC calorimeter during the LEP2 programme

  • Author/Authors

    Feindt، نويسنده , , M. and Grahl، نويسنده , , J. and Kreuter، نويسنده , , C. and Ragazzi، نويسنده , , S. and Tabarelli de Fatis، نويسنده , , T. and Tonazzo، نويسنده , , A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    6
  • From page
    69
  • To page
    74
  • Abstract
    The readout chambers of the DELPHI HPC calorimeter are affected by large ageing which results in a module-dependent loss of gain. The calorimeter response thus needs to be tuned on a module-by-module basis. During the LEP operation phase at energies close to the Z resonance (LEP1), the tuning was based on the high available statistics of Z→e+e− events. In the high energy operation phase (LEP2), no such clear monochromatic physics channel is available with high statistics. A monitoring of the analog response of the readout chambers of each module is provided by the periodic calibration with radioactive 83mKr; using this information to account for module-dependent effects ensures the stability of the energy resolution throughout the LEP2 programme.
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1999
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2180287