Title of article :
Calibration of the DELPHI HPC calorimeter during the LEP2 programme
Author/Authors :
Feindt، نويسنده , , M. and Grahl، نويسنده , , J. and Kreuter، نويسنده , , C. and Ragazzi، نويسنده , , S. and Tabarelli de Fatis، نويسنده , , T. and Tonazzo، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
6
From page :
69
To page :
74
Abstract :
The readout chambers of the DELPHI HPC calorimeter are affected by large ageing which results in a module-dependent loss of gain. The calorimeter response thus needs to be tuned on a module-by-module basis. During the LEP operation phase at energies close to the Z resonance (LEP1), the tuning was based on the high available statistics of Z→e+e− events. In the high energy operation phase (LEP2), no such clear monochromatic physics channel is available with high statistics. A monitoring of the analog response of the readout chambers of each module is provided by the periodic calibration with radioactive 83mKr; using this information to account for module-dependent effects ensures the stability of the energy resolution throughout the LEP2 programme.