Title of article :
Simulation of neutral beam tomography using maximum entropy method
Author/Authors :
Wook Lee، نويسنده , , Seung and Cho، نويسنده , , Gyuseong and Sub Cho، نويسنده , , Yong and Ho Choi، نويسنده , , Byung، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
5
From page :
693
To page :
697
Abstract :
A tomography algorithm to maximize the entropy of an image was used for the reconstruction of 2D spatial distribution of intense neutral beams, such as triple beams of KSTAR NBI (Korea Superconducting Tokamak Advanced Research Neutral Beam Injector). A possible detection system was modeled by system geometry parameters and numerical simulations were done to test the reconstruction fidelity of simulated beam profiles. First of all, we simulated with changes of number of cameras and 11 cameras were proposed from this simulation. The simulations with changes of noise level were also done and their relationships with reconstruction fidelity were shown.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1999
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2180476
Link To Document :
بازگشت