Title of article :
Neutron detection with imaging plates Part II. Detector characteristics
Author/Authors :
Thoms، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
6
From page :
34
To page :
39
Abstract :
On the basis of the physical processes described in Neutron detection with imaging plates – part I: image storage and readout [Nucl. Instr. and Meth. A 424 (1999) 26–33] detector characteristics, such as quantum efficiency, detective quantum efficiency, sensitivity to neutron- and γ-radiation, readout time and dynamic range are predicted. It is estimated that quantum efficiencies and detective quantum efficiencies close to 100% can be reached making these kind of detectors interesting for a wide range of applications.
Keywords :
:  , Imaging plate , Light Scattering , BaFBr  , photostimulated luminescence , Storage phosphor , EU , Neutron converter
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1999
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2180616
Link To Document :
بازگشت