Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography
Author/Authors :
Asano، نويسنده , , H and Takenaka، نويسنده , , N and Fujii، نويسنده , , T and Shibata، نويسنده , , Y and Ebisu، نويسنده , , T and Matsubayashi، نويسنده , , M، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
6
From page :
98
To page :
103
Abstract :
The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.
Keywords :
Capillary tube , Distributor , Neutron radiography , Compression-type refrigerator , Gas–liquid two-phase flow , Void fraction , Flashing