Title of article :
Beam optics design of the REX-ISOLDE q/m-separator
Author/Authors :
Rao، نويسنده , , R. and Kester، نويسنده , , Lars O. and Sieber، نويسنده , , T. and Habs، نويسنده , , D. L. Rudolph، نويسنده , , K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
7
From page :
170
To page :
176
Abstract :
In the radioactive beam experiment (REX) at ISOLDE/CERN radioactive singly charged ions are delivered by the online mass separator ISOLDE and are accelerated up to 2.2 MeV/u by a new concept, using a linear accelerator consisting of a RFQ accelerator, an IH-structure and three 7-gap-resonators (Habs et al., Nucl. Instr. and Meth. B 126 (1997) 218). The ions coming from ISOLDE are first accumulated, bunched and cooled in a Penning Ion Trap (REXTRAP), which is similar to ISOLTRAP (Bollen et al., Nucl. Instr. and Meth. A 368 (1996) 675). Then, in an electron beam ion source (REXEBIS) charge multiplication takes place. Finally, the highly charged ions are accelerated in the LINAC. As the ions coming out from the EBIS contain impurities coming from residual gas inside the EBIS, an accurate q/m selection is necessary before the beam is injected into the RFQ accelerator. This paper presents the design of the REX-ISOLDE separator.
Keywords :
Gaussian beam , RFQ accelerator , REX-ISOLDE , Radioactive isotopes
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1999
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2181192
Link To Document :
بازگشت