Title of article :
Plasma effects for heavy ions in implanted silicon detectors
Author/Authors :
Aiello، نويسنده , , S and Anzalone، نويسنده , , A and Campisi، نويسنده , , M.G and Cardella، نويسنده , , G and Cavallaro، نويسنده , , Sl and Filippo، نويسنده , , E.De and Geraci، نويسنده , , E and Geraci، نويسنده , , M and Guazzoni، نويسنده , , P and Manno، نويسنده , , M.C.Iacono and Lanzalone، نويسنده , , G and Lanzano، نويسنده , , G and Nigro، نويسنده , , S.Lo and Pagano، نويسنده , , A and Papa، نويسنده , , M and Pirrone، نويسنده , , S and P، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
8
From page :
510
To page :
517
Abstract :
Plasma effects for heavy ions in implanted silicon detectors have been investigated for different detector characteristics as a function of type and energy of the detected particles. A new approach is presented and used to reproduce the effect of the plasma delay in the timing performances. The results are in good agreement with the present data and with previous measurements found in the literature.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1999
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2181305
Link To Document :
بازگشت