    Carman، نويسنده , , D.S. and Bland، نويسنده , , L.C. and Chant، نويسنده , , N.S. and Eads، نويسنده , , A. and Gu، نويسنده , , T. and Huber، نويسنده , , G.M. and Huffman، نويسنده , , J. and Klyachko، نويسنده , , A. and Markham، نويسنده , , B.C. and Roos، نويسنده , , P.G. and Schwandt، نويسنده , , P. and Solberg، نويسنده , , K.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    18
  • From page
    382
  • To page
    399
  • Abstract
    A neutron detector with moderate energy resolution (∼3 MeV) has been built for neutrons in the energy range 75–175 MeV. The detector was designed for coincidence scattering experiments. The design eliminates the need for long neutron flight paths necessary for comparable energy resolution time-of-flight measurements with a comparable efficiency-solid angle product (0.02 msr). The detector consists of thin plastic scintillators in which the neutron undergoes n–p elastic scattering. The second-scattered protons are tracked by drift chambers and detected in a sodium iodide array. The design motivations and features are presented along with results from detailed in-beam experimental tests.