Title of article :
Intensity enhancement of cold neutrons from a coupled liquid-hydrogen moderator for pulsed cold neutron sources
Author/Authors :
Ogawa، نويسنده , , Y. and Kiyanagi، نويسنده , , Y. and Kosugi، نويسنده , , N. and Iwasa، نويسنده , , H. and Furusaka، نويسنده , , M. and Watanabe، نويسنده , , N.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
7
From page :
415
To page :
421
Abstract :
In order to obtain higher cold neutron intensity from a coupled liquid-hydrogen moderator with a premoderator for pulsed cold neutron sources, we examined a partial enhancement method, namely, narrow beam extraction for both a flat liquid-hydrogen moderator and a single-groove one. Combined with the narrow beam extraction, which is especially suitable for small-angle scattering and neutron reflectometry experiments, a single-groove moderator provides higher intensity, by about 30%, than a flat-surface moderator at the region of interest on a viewed surface. The effect of double-side beam extraction from such moderators on the intensity gain factor is also discussed.
Keywords :
Coupled liquid-hydrogen moderator , Accelerator-based pulsed neutron source , Narrow beam extraction , Single-groove moderator
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1999
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2182182
Link To Document :
بازگشت