    Measurement of absorbed dose by 7-GeV bremsstrahlung in a PMMA phantom

  • Author/Authors

    Job، نويسنده , , P.K. and Pisharody، نويسنده , , M. and Semones، نويسنده , , E.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    8
  • From page
    540
  • To page
    547
  • Abstract
    High-energy electron storage rings generate energetic bremsstrahlung photons through radiative interaction of the particle beam with the residual gas molecules and other components inside the storage ring. At synchrotron radiation facilities, where beamlines are channeled out of the storage ring, a continuous bremsstrahlung spectrum, with a maximum energy of the stored particle beam, will be present. At the advanced photon source (APS), where the stored beam energy is 7 GeV, bremsstrahlung generated in the straight sections of the insertion device beamlines, which are a total of 15.38 m in length, can be significant. The contribution from each bremsstrahlung interaction adds up to produce a narrow mono-directional bremsstrahlung beam that comes down through the insertion device beamlines. The resulting absorbed dose distributions by this radiation in a 300 mm×300 mm×300 mm tissue substitute cube phantom were measured with LiF:Mg,Ti (TLD-700) thermoluminescent dosemeters. The normalized absorbed dose, in a cross-sectional area of 100 mm2 at a depth of 150 mm of the PMMA phantom, was measured as 3.3×106 mGy h−1W−1 for 7-GeV bremsstrahlung spectrum.