Title of article :
Direct measurement of electron bunch shapes and coherent undulator radiation produced by 100 femtosecond structure
Author/Authors :
Ricci، نويسنده , , K.N and Crosson، نويسنده , , E.R and Smith، نويسنده , , T.I، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
At the Stanford FEL Center, magnetic longitudinal dispersion has been used to improve the well-known technique of measuring electron bunch time-profiles with off-phase acceleration and an energy spectrometer. This unambiguous direct method allowed us to measure, without extrapolation or the mathematical reconstructions of other high-resolution techniques, a variety of bunch profiles at approximately 100 fs resolution – including asymmetric bunches with a single extremely narrow peak. The sharply peaked bunches generated far-infrared undulator radiation two orders of magnitude brighter than bunches without such structure. A Fabry–Perot-type scan of the undulator radiation indicated nearly 100% coherence of the radiation from the brightest bunches, and provided optical evidence consistent with the bunch shape measurements.
Keywords :
Accelerator beam diagnostic , Coherent undulator radiation
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A