Title of article :
Study and optimization of the electron beam transport line of the FEL CLIO
Author/Authors :
Rippon، نويسنده , , C، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
The CLIO infrared free electron laser (FEL) electron transport system has been optimized for FEL operation above 16 μm which required electron energies below 32 MeV. Achromaticity has been optimized at the undulator entrance. Measurements confirm the optimization procedure. At lower energies, a magnetic pulse compression effect leads to an enhancement of the peak current.
Keywords :
Magnetic compression , Undulator , Peak current , Beam optics dynamic , Achromaticity , Isochronicity
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :