Title of article
The ZEUS microvertex detector
Author/Authors
Coldewey، نويسنده , , C.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
11
From page
44
To page
54
Abstract
For the HERA luminosity upgrade in the year 2000, the ZEUS experiment is preparing a high-precision vertex detector using single-sided silicon microstrip detectors with capacitive charge division. The readout pitch of the detectors is 120 μm with five intermediate strips. The paper reviews the design of the microvertex detector consisting of a central part with three double layers and four wheels in the forward region. Results on electrical measurements before and after irradiation on the detectors and on the test structures designed for quality-control measurements are presented. For a number of prototype detectors mounted to the prototype readout electronics (HELIX-128) the pulse height distribution and the position resolution has been measured in a test beam using 6 GeV electrons. The expected position resolution of about 7.5 μm at normal incidence has been achieved.
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2000
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2186416
Link To Document