Title of article :
Performance of the ZEUS forward plug calorimeter
Author/Authors :
Goebel، نويسنده , , Florian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
3
From page :
230
To page :
232
Abstract :
With the installation of a forward plug calorimeter (FPC) the calorimetric coverage of the ZEUS detector has been extended by one unit in pseudorapidity (ZEVS FPC group, Nucl. Instr. and Meth., in print). The FPC is a compensating shashlik-type calorimeter with layers of 15 mm thick Pb and 2.6 mm thick organic scintillators. The light is read out with WLS fibers and PMTs. Before installation in ZEUS the FPC has been tested and calibrated with test beams of 10–100 GeV. Long-term stability is monitored with a 60Co source.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2000
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2187769
Link To Document :
بازگشت