Title of article :
Aerogel Cherenkov counters for the KEDR detector
Author/Authors :
Barnyakov، نويسنده , , M.Yu and Bobrovnikov، نويسنده , , V.S. and Buzykaev، نويسنده , , A.R. and Danilyuk، نويسنده , , A.F. and Ganzhur، نويسنده , , S.F. and Goldberg، نويسنده , , I.I. and Kolachev، نويسنده , , G.M. and Kononov، نويسنده , , S.A. and Kravchenko، نويسنده , , E.A. and Minakov، نويسنده , , G.D and Onuchin، نويسنده , , A.P and Savinov، نويسنده , , G.A and Tayursky، نويسنده , , V.A، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
5
From page :
326
To page :
330
Abstract :
The project of Cherenkov counters based on Aerogel, wavelength SHIfter, and PHotomultiplier (ASHIPH) for the KEDR detector is described. The Monte Carlo simulation of number of photoelectrons was carried out. The first counters have been produced. Measurements with cosmic particles were performed. As compared with the direct light collection on PMT, the ASHIPH method allows the diminishment of the number of PMTs essentially. The optical properties of aerogels produced at KEK and at Novosibirsk are presented.
Keywords :
Wavelength shifters , Particle identification , aerogel , Monte Carlo
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2000
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2187854
Link To Document :
بازگشت